Exploratory Comparison of Right-Angle and Front-Face Geometries Using EEM Fluorescence Spectroscopy Coupled with PARAFAC for the Analysis of Arthrospira platensis from Lake Chad

Zoutchibé Joseph

Département de Physique, Faculté des Sciences Exactes et Appliquées, Université de N’Djaména, B.P.1027 N’Djaména, Chad and Laboratoire Optique et Applications, Centre of Atomic Molecular Physics and Quantum Optics, Faculty of Sciences, University of Douala, B.P. 8580 Douala, Cameroon.

Palé Wang-Yang *

Laboratoire Optique et Applications, Centre of Atomic Molecular Physics and Quantum Optics, Faculty of Sciences, University of Douala, B.P. 8580 Douala, Cameroon and Département de Mathématique-Physique, Université Catholique Saint Charles Lwanga, BP 169 Sahr, Chad.

Beunoné Davy

Département de Génie Mécanique, Faculté de Sciences et Techniques de l’ingénieur, Université Polytechnique de Mongo, BP4377 Mongo, Chad.

Yacoub Idriss Halawlaw

Département de Physique, Faculté des Sciences Exactes et Appliquées, Université de N’Djaména, B.P.1027 N’Djaména, Chad.

Kenfack Cyril Assongo

Laboratoire Optique et Applications, Centre of Atomic Molecular Physics and Quantum Optics, Faculty of Sciences, University of Douala, B.P. 8580 Douala, Cameroon.

Koyambo-Konzapa Stève-Jonathan

Laboratoire Matière, Énergie et Rayonnement (LAMER), Université de Bangui, Bangui, Central African Republic.

*Author to whom correspondence should be addressed.


Abstract

Excitation–emission matrix (EEM) fluorescence spectroscopy coupled with parallel factor analysis (PARAFAC) can characterise complex algal matrices, but comparisons between acquisition geometries may be affected by sample preparation. This exploratory study compares right-angle (90°) and front-face fluorescence excitation–emission matrices (EEMs) and four-component PARAFAC models for Arthrospira platensis from the Lake Chad region. Seventeen distinct samples were investigated: sixteen regional samples and one commercial Arkopharma product analysed in duplicate, giving eighteen measurements per geometry. EEMs were recorded using a modular in-house spectrofluorometer over excitation and emission ranges of 270-610 nm and 280-800 nm, respectively, with a 2 nm increment and a 0.4 s integration time. The four-component models explained 96.70% and 96.47% of the variance, with core consistency diagnostic (CORCONDIA) values of 61.42% and 51.98% for right-angle and front-face measurements, respectively. The corresponding excitation/emission maxima were 370/452, 610/662, 390/464, and 590/626 nm, and 370/458, 610/666, 380/466, and 590/642 nm. Emission maxima differed by 2-16 nm, and relative scores also differed. These are descriptive observations: diluted solutions were used at 90°, whereas undiluted solutions were used in front-face geometry. Geometry and concentration are therefore confounded. The available results establish an exploratory comparison of two acquisition protocols; they do not establish geometry-specific sensitivity, reproducibility, or equivalence. Matched-concentration measurements, technical replication, and quantitative profile comparisons are required to test those properties.

Keywords: Fluorescence, excitation–emission matrix, PARAFAC, front-face, right-angle, Arthrospira platensis, Lake Chad


How to Cite

Joseph, Zoutchibé, Palé Wang-Yang, Beunoné Davy, Yacoub Idriss Halawlaw, Kenfack Cyril Assongo, and Koyambo-Konzapa Stève-Jonathan. 2026. “Exploratory Comparison of Right-Angle and Front-Face Geometries Using EEM Fluorescence Spectroscopy Coupled With PARAFAC for the Analysis of Arthrospira Platensis from Lake Chad”. International Research Journal of Pure and Applied Chemistry 27 (6):163-74. https://doi.org/10.9734/irjpac/2026/v27i61055.

Downloads

Download data is not yet available.